Standard single-mode optical fiber "PureBand?" "PureAccess?" series
Overview
Single Mode Fibers (SMF), PureBand? and PureAccess? series are widely used for Backbone, Core, Metro, Access and FTTH.
Features
Wide market application
Reliable supply with 40 years’ experience
Worldwide support
Products
【G.652.D】
PureBand?
Low Water Peak Single-Mode Optical Fiber
ITU-T G.652.D
-
Peace of mind from a market-leading reliability
PureBand?[LL]
Low Water Peak Single-Mode Optical Fiber
ITU-T G.652.D
-
The optimum, low-loss choice for high performance terrestrial applications
【G.652.D/G.657.A1】
PureBand?-PLUS
Bend Insensitive Single-Mode Optical Fiber
ITU-T G.652.D/G.657.A1
-
Enables a more compact cabling construction for access and FTTH applications
-
Higher fiber density of cable and smaller outer cable diameter
-
More effective use of existing, limited space
PureBand?-R
Bend Insensitive Single-Mode Optical Fiber
ITU-T G.652.D/G.657.A1
-
Enables a more compact cabling construction for access and FTTH applications
-
Higher fiber density of cable and smaller outer cable diameter
-
More effective use of existing limited space
PureBand?-R[LL]
Bend Insensitive Single-Mode Optical Fiber
ITU-T G.652.D/G.657.A1
-
A robust versatility with Low-loss and superior bending performance
-
Optimises inventory control for cable makers - one fiber for all applications
-
Higher fiber density of cable and smaller outer cable diameter
-
More effective use of existing limited space
PureAccess?
Bend Insensitive Single-Mode Optical Fiber
ITU-T G.652.D/G.657.A1
-
Enables a more compact cabling construction
-
Higher fiber density of cable and smaller outer cable diameter
-
More effective use of existing limited space
-
Peace of mind from a market-leading reliability
* Depends on the coating diameter. Please download and check out our product data sheets below
【G.652.D/G.657.A2】
PureAccess?[A2]
Bend Insensitive Single-Mode Optical Fiber
ITU-T G.652.D/G.657.A2
-
Enables a more compact cabling construction
-
Higher fiber density of cable and smaller outer cable diameter
-
More effective use of existing limited space
-
Peace of mind from a market-leading reliability
* Depends on the coating diameter. Please download and check out our product data sheets below
Performance Comparison
| Product Name | PureBand? | PureBand? [LL] | PureBand?-Plus | PureBand?-R | PureBand?-R [LL] | PureAccess? | PureAccess? [A2] |
|---|---|---|---|---|---|---|---|
| Standards Compliance | G.652.D | G.652.D | G.652.D/ G.657.A1 | G.652.D/ G.657.A1 | G.652.D/ G.657.A1 | G.652.D/ G.657.A1 | G.652.D G.657.A2 |
| Available Coating Diameter | 250 ?m | 250 ?m | 250 ?m 200 ?m | 250 ?m 200 ?m | 250 ?m 200 ?m | 250 ?m 200 ?m 180 ?m | 250 ?m 200 ?m 180 ?m |
| Minimum Bending Radius | 25 mm | 25 mm | 10 mm | 10 mm | 10 mm | 10 mm | 7.5 mm |
| Mode Field Diameter at 1310 nm | 9.2 ± 0.4 ?m | 9.2 ± 0.4 ?m | 8.9 ± 0.4 ?m | 9.2 ± 0.4 ?m | 9.2 ± 0.4 ?m | 8.6 ± 0.4 ?m | 8.6 ± 0.4 ?m |
| Cable Cut-off Wavelength | ≤ 1260 nm | ≤ 1260 nm | ≤ 1260 nm | ≤ 1260 nm | ≤ 1260 nm | ≤ 1260 nm | ≤ 1260 nm |
| Attenuation at 1310 nm | ≤ 0.35 dB/km | ≤ 0.32 dB/km | ≤ 0.35 dB/km | ≤ 0.35 dB/km | ≤ 0.32 dB/km | ≤ 0.35 dB/km | ≤ 0.35 dB/km |
| Attenuation at 1383 nm (After H2 aging) | ≤ 0.35 dB/km | ≤ 0.32 dB/km | ≤ 0.35 dB/km | ≤ 0.35 dB/km | ≤ 0.32 dB/km | ≤ 0.35 dB/km | ≤ 0.35 dB/km |
| Attenuation at 1550 nm | ≤ 0.20 dB/km | ≤ 0.18 dB/km | ≤ 0.20 dB/km | ≤ 0.20 dB/km | ≤ 0.18 dB/km | ≤ 0.21 dB/km | ≤ 0.21 dB/km |
| Attenuation at 1625 nm | ≤ 0.23 dB/km | ≤ 0.20 dB/km | ≤ 0.23 dB/km | ≤ 0.23 dB/km | ≤ 0.20 dB/km | ≤ 0.22 dB/km | ≤ 0.22 dB/km |
| Zero Dispersion Wavelength | 1300–1324 nm | 1300–1324 nm | 1300–1324 nm | 1300–1324 nm | 1300–1324 nm | 1300–1324 nm | 1300–1324 nm |
| PMD Link Design Value | ≤ 0.06 ps/√km | ≤ 0.06 ps/√km | ≤ 0.06 ps/√km | ≤ 0.06 ps/√km | ≤ 0.06 ps/√km | ≤ 0.06 ps/√km | ≤ 0.06 ps/√km |